Also, the distributor drive... Also, the distributor drive comes setup with a timing pointer that can be used with a harmonic dampener like the ATI piece that Bowers used. A Meziere electric water pump easily cleared the adapter and made it easy to keep the heat down.
| DYNO DATA |
| Best Qualifying Pull |
| RPM |
TQ |
HP |
| 3,000 |
407 |
232 |
| 3,100 |
410 |
242 |
| 3,200 |
407 |
248 |
| 3,300 |
402 |
252 |
| 3,400 |
398 |
257 |
| 3,500 |
392 |
261 |
| 3,600 |
388 |
266 |
| 3,700 |
386 |
272 |
| 3,800 |
388 |
281 |
| 3,900 |
396 |
296 |
| 4,000 |
414 |
316 |
| 4,100 |
432 |
337 |
| 4,200 |
447 |
358 |
| 4,300 |
460 |
377 |
| 4,400 |
470 |
394 |
| 4,500 |
479 |
410 |
| 4,600 |
487 |
426 |
| 4,700 |
490 |
439 |
| 4,800 |
493 |
451 |
| 4,900 |
499 |
465 |
| 5,000 |
500 |
476 |
| 5,100 |
498 |
484 |
| 5,200 |
499 |
494 |
| 5,300 |
499 |
504 |
| 5,400 |
498 |
512 |
| 5,500 |
498 |
521 |
| 5,600 |
497 |
530 |
| 5,700 |
495 |
537 |
| 5,800 |
492 |
544 |
| 5,900 |
490 |
551 |
| 6,000 |
489 |
559 |
| 6,100 |
487 |
565 |
| 6,200 |
483 |
570 |
| 6,300 |
480 |
576 |
| 6,400 |
474 |
578 |
| 6,500 |
468 |
579 |
| 6,600 |
461 |
579 |
| 6,700 |
452 |
577 |
| 6,800 |
446 |
577 |
| 6,900 |
440 |
578 |
| 7,000 |
433 |
578 |
|